kube/monitoring/snmp-configs.yaml

1274 lines
36 KiB
YAML

epson_beamer:
get:
- 1.3.6.1.4.1.1248.4.1.1.1.1.0
- 1.3.6.1.4.1.1248.4.1.1.2.7.0
- 1.3.6.1.4.1.1248.4.1.1.1.8.0
- 1.3.6.1.4.1.1248.4.1.1.2.2.0
- 1.3.6.1.4.1.1248.4.1.1.1.9.0
- 1.3.6.1.4.1.1248.4.1.1.2.1.0
metrics:
- name: EpsonLampHours
oid: 1.3.6.1.4.1.1248.4.1.1.1.1.0
type: counter
- name: EpsonName
oid: 1.3.6.1.4.1.1248.4.1.1.2.7.0
type: DisplayString
- name: EpsonFirmwareVersion
oid: 1.3.6.1.4.1.1248.4.1.1.1.8.0
type: DisplayString
- name: EpsonInputSource
oid: 1.3.6.1.4.1.1248.4.1.1.2.2.0
type: DisplayString
- name: EpsonProjectorStatus
oid: 1.3.6.1.4.1.1248.4.1.1.1.9.0
type: DisplayString
# "01 0000 0000 T1": "Standby OK OK"
# "01 0000 0001 T1": "Standby OK Lamp ON failure"
# "01 0000 0002 T1": "Standby OK Lamp lid"
# "01 0000 0003 T1": "Standby OK Lamp burnout (ON, then OFF)"
# "01 0000 0004 T1": "Standby OK Fan"
- name: EpsonPower
oid: 1.3.6.1.4.1.1248.4.1.1.2.1.0
help: on or off
type: gauge
printer_mib:
version: 1
walk:
- 1.3.6.1.2.1.25.3.5.1.1
- 1.3.6.1.2.1.43.11.1.1.5
- 1.3.6.1.2.1.43.11.1.1.6
- 1.3.6.1.2.1.43.11.1.1.8
- 1.3.6.1.2.1.43.11.1.1.9
- 1.3.6.1.2.1.43.5.1.1.13
- 1.3.6.1.2.1.43.5.1.1.16
- 1.3.6.1.2.1.43.5.1.1.17
- 1.3.6.1.2.1.43.5.1.1.18
- 1.3.6.1.2.1.43.5.1.1.19
- 1.3.6.1.2.1.43.5.1.1.3
- 1.3.6.1.2.1.43.6.1.1.3
get:
- 1.3.6.1.2.1.1.3.0
metrics:
- name: sysUpTime
oid: 1.3.6.1.2.1.1.3
type: gauge
help: The time (in hundredths of a second) since the network management portion
of the system was last re-initialized. - 1.3.6.1.2.1.1.3
- name: hrPrinterStatus
oid: 1.3.6.1.2.1.25.3.5.1.1
type: EnumAsStateSet
help: The current status of this printer device. - 1.3.6.1.2.1.25.3.5.1.1
indexes:
- labelname: hrDeviceIndex
type: gauge
enum_values:
1: other
2: unknown
3: idle
4: printing
5: warmup
- name: prtMarkerSuppliesType
oid: 1.3.6.1.2.1.43.11.1.1.5
type: gauge
help: The type of this supply. - 1.3.6.1.2.1.43.11.1.1.5
indexes:
- labelname: hrDeviceIndex
type: gauge
- labelname: prtMarkerSuppliesIndex
type: gauge
lookups:
- labels:
- hrDeviceIndex
- prtMarkerSuppliesIndex
labelname: prtMarkerSuppliesType
oid: 1.3.6.1.2.1.43.11.1.1.5
type: gauge
enum_values:
1: other
2: unknown
3: toner
4: wasteToner
5: ink
6: inkCartridge
7: inkRibbon
8: wasteInk
9: opc
10: developer
11: fuserOil
12: solidWax
13: ribbonWax
14: wasteWax
15: fuser
16: coronaWire
17: fuserOilWick
18: cleanerUnit
19: fuserCleaningPad
20: transferUnit
21: tonerCartridge
22: fuserOiler
23: water
24: wasteWater
25: glueWaterAdditive
26: wastePaper
27: bindingSupply
28: bandingSupply
29: stitchingWire
30: shrinkWrap
31: paperWrap
32: staples
33: inserts
34: covers
35: matteToner
36: matteInk
- name: prtMarkerSuppliesDescription
oid: 1.3.6.1.2.1.43.11.1.1.6
type: DisplayString
help: The description of this supply container/receptacle in the localization
specified by prtGeneralCurrentLocalization. - 1.3.6.1.2.1.43.11.1.1.6
indexes:
- labelname: hrDeviceIndex
type: gauge
- labelname: prtMarkerSuppliesIndex
type: gauge
lookups:
- labels:
- hrDeviceIndex
- prtMarkerSuppliesIndex
labelname: prtMarkerSuppliesType
oid: 1.3.6.1.2.1.43.11.1.1.5
type: gauge
- name: prtMarkerSuppliesMaxCapacity
oid: 1.3.6.1.2.1.43.11.1.1.8
type: gauge
help: The maximum capacity of this supply container/receptacle expressed in prtMarkerSuppliesSupplyUnit
- 1.3.6.1.2.1.43.11.1.1.8
indexes:
- labelname: hrDeviceIndex
type: gauge
- labelname: prtMarkerSuppliesIndex
type: gauge
lookups:
- labels:
- hrDeviceIndex
- prtMarkerSuppliesIndex
labelname: prtMarkerSuppliesType
oid: 1.3.6.1.2.1.43.11.1.1.5
type: gauge
- name: prtMarkerSuppliesLevel
oid: 1.3.6.1.2.1.43.11.1.1.9
type: gauge
help: The current level if this supply is a container; the remaining space if
this supply is a receptacle - 1.3.6.1.2.1.43.11.1.1.9
indexes:
- labelname: hrDeviceIndex
type: gauge
- labelname: prtMarkerSuppliesIndex
type: gauge
lookups:
- labels:
- hrDeviceIndex
- prtMarkerSuppliesIndex
labelname: prtMarkerSuppliesType
oid: 1.3.6.1.2.1.43.11.1.1.5
type: gauge
- name: prtConsoleDisable
oid: 1.3.6.1.2.1.43.5.1.1.13
type: EnumAsStateSet
help: This value indicates how input is (or is not) accepted from the operator
console - 1.3.6.1.2.1.43.5.1.1.13
indexes:
- labelname: hrDeviceIndex
type: gauge
enum_values:
3: enabled
4: disabled
- name: prtGeneralPrinterName
oid: 1.3.6.1.2.1.43.5.1.1.16
type: DisplayString
help: An administrator-specified name for this printer - 1.3.6.1.2.1.43.5.1.1.16
indexes:
- labelname: hrDeviceIndex
type: gauge
- name: prtGeneralSerialNumber
oid: 1.3.6.1.2.1.43.5.1.1.17
type: DisplayString
help: A recorded serial number for this device that indexes some type device catalog
or inventory - 1.3.6.1.2.1.43.5.1.1.17
indexes:
- labelname: hrDeviceIndex
type: gauge
- name: prtAlertCriticalEvents
oid: 1.3.6.1.2.1.43.5.1.1.18
type: counter
help: A running counter of the number of critical alert events that have been
recorded in the alert table - 1.3.6.1.2.1.43.5.1.1.18
indexes:
- labelname: hrDeviceIndex
type: gauge
- name: prtAlertAllEvents
oid: 1.3.6.1.2.1.43.5.1.1.19
type: counter
help: A running counter of the total number of alert event entries (critical and
non-critical) that have been recorded in the alert table - 1.3.6.1.2.1.43.5.1.1.19
indexes:
- labelname: hrDeviceIndex
type: gauge
- name: prtGeneralReset
oid: 1.3.6.1.2.1.43.5.1.1.3
type: EnumAsStateSet
help: Setting this value to 'powerCycleReset', 'resetToNVRAM', or 'resetToFactoryDefaults'
will result in the resetting of the printer - 1.3.6.1.2.1.43.5.1.1.3
indexes:
- labelname: hrDeviceIndex
type: gauge
enum_values:
3: notResetting
4: powerCycleReset
5: resetToNVRAM
6: resetToFactoryDefaults
- name: prtCoverStatus
oid: 1.3.6.1.2.1.43.6.1.1.3
type: EnumAsStateSet
help: The status of this cover sub-unit. - 1.3.6.1.2.1.43.6.1.1.3
indexes:
- labelname: hrDeviceIndex
type: gauge
- labelname: prtCoverIndex
type: gauge
enum_values:
1: other
2: unknown
3: coverOpen
4: coverClosed
5: interlockOpen
6: interlockClosed
rfc1628_ups:
walk:
- 1.3.6.1.2.1.2
- 1.3.6.1.2.1.33.1.1
- 1.3.6.1.2.1.33.1.2
- 1.3.6.1.2.1.33.1.3
- 1.3.6.1.2.1.33.1.4
- 1.3.6.1.2.1.33.1.5
- 1.3.6.1.2.1.33.1.6
- 1.3.6.1.2.1.33.1.7
- 1.3.6.1.2.1.33.1.8
- 1.3.6.1.2.1.33.1.9
get:
- 1.3.6.1.2.1.1.3.0
metrics:
- name: sysUpTime
oid: 1.3.6.1.2.1.1.3
type: gauge
help: The time (in hundredths of a second) since the network management portion
of the system was last re-initialized. - 1.3.6.1.2.1.1.3
- name: ifNumber
oid: 1.3.6.1.2.1.2.1
type: gauge
help: The number of network interfaces (regardless of their current state) present
on this system. - 1.3.6.1.2.1.2.1
- name: ifIndex
oid: 1.3.6.1.2.1.2.2.1.1
type: gauge
help: A unique value for each interface - 1.3.6.1.2.1.2.2.1.1
indexes:
- labelname: ifIndex
type: gauge
lookups:
- labels:
- ifIndex
labelname: ifDescr
oid: 1.3.6.1.2.1.2.2.1.2
type: DisplayString
- labels: []
labelname: ifIndex
- name: ifDescr
oid: 1.3.6.1.2.1.2.2.1.2
type: DisplayString
help: A textual string containing information about the interface - 1.3.6.1.2.1.2.2.1.2
indexes:
- labelname: ifIndex
type: gauge
lookups:
- labels:
- ifIndex
labelname: ifDescr
oid: 1.3.6.1.2.1.2.2.1.2
type: DisplayString
- labels: []
labelname: ifIndex
- name: ifType
oid: 1.3.6.1.2.1.2.2.1.3
type: EnumAsInfo
help: The type of interface - 1.3.6.1.2.1.2.2.1.3
indexes:
- labelname: ifIndex
type: gauge
lookups:
- labels:
- ifIndex
labelname: ifDescr
oid: 1.3.6.1.2.1.2.2.1.2
type: DisplayString
- labels: []
labelname: ifIndex
enum_values:
1: other
2: regular1822
3: hdh1822
4: ddnX25
5: rfc877x25
6: ethernetCsmacd
7: iso88023Csmacd
8: iso88024TokenBus
9: iso88025TokenRing
10: iso88026Man
11: starLan
12: proteon10Mbit
13: proteon80Mbit
14: hyperchannel
15: fddi
16: lapb
17: sdlc
18: ds1
19: e1
20: basicISDN
21: primaryISDN
22: propPointToPointSerial
23: ppp
24: softwareLoopback
25: eon
26: ethernet3Mbit
27: nsip
28: slip
29: ultra
30: ds3
31: sip
32: frameRelay
33: rs232
34: para
35: arcnet
36: arcnetPlus
37: atm
38: miox25
39: sonet
40: x25ple
41: iso88022llc
42: localTalk
43: smdsDxi
44: frameRelayService
45: v35
46: hssi
47: hippi
48: modem
49: aal5
50: sonetPath
51: sonetVT
52: smdsIcip
53: propVirtual
54: propMultiplexor
55: ieee80212
56: fibreChannel
57: hippiInterface
58: frameRelayInterconnect
59: aflane8023
60: aflane8025
61: cctEmul
62: fastEther
63: isdn
64: v11
65: v36
66: g703at64k
67: g703at2mb
68: qllc
69: fastEtherFX
70: channel
71: ieee80211
72: ibm370parChan
73: escon
74: dlsw
75: isdns
76: isdnu
77: lapd
78: ipSwitch
79: rsrb
80: atmLogical
81: ds0
82: ds0Bundle
83: bsc
84: async
85: cnr
86: iso88025Dtr
87: eplrs
88: arap
89: propCnls
90: hostPad
91: termPad
92: frameRelayMPI
93: x213
94: adsl
95: radsl
96: sdsl
97: vdsl
98: iso88025CRFPInt
99: myrinet
100: voiceEM
101: voiceFXO
102: voiceFXS
103: voiceEncap
104: voiceOverIp
105: atmDxi
106: atmFuni
107: atmIma
108: pppMultilinkBundle
109: ipOverCdlc
110: ipOverClaw
111: stackToStack
112: virtualIpAddress
113: mpc
114: ipOverAtm
115: iso88025Fiber
116: tdlc
117: gigabitEthernet
118: hdlc
119: lapf
120: v37
121: x25mlp
122: x25huntGroup
123: transpHdlc
124: interleave
125: fast
126: ip
127: docsCableMaclayer
128: docsCableDownstream
129: docsCableUpstream
130: a12MppSwitch
131: tunnel
132: coffee
133: ces
134: atmSubInterface
135: l2vlan
136: l3ipvlan
137: l3ipxvlan
138: digitalPowerline
139: mediaMailOverIp
140: dtm
141: dcn
142: ipForward
143: msdsl
144: ieee1394
145: if-gsn
146: dvbRccMacLayer
147: dvbRccDownstream
148: dvbRccUpstream
149: atmVirtual
150: mplsTunnel
151: srp
152: voiceOverAtm
153: voiceOverFrameRelay
154: idsl
155: compositeLink
156: ss7SigLink
157: propWirelessP2P
158: frForward
159: rfc1483
160: usb
161: ieee8023adLag
162: bgppolicyaccounting
163: frf16MfrBundle
164: h323Gatekeeper
165: h323Proxy
166: mpls
167: mfSigLink
168: hdsl2
169: shdsl
170: ds1FDL
171: pos
172: dvbAsiIn
173: dvbAsiOut
174: plc
175: nfas
176: tr008
177: gr303RDT
178: gr303IDT
179: isup
180: propDocsWirelessMaclayer
181: propDocsWirelessDownstream
182: propDocsWirelessUpstream
183: hiperlan2
184: propBWAp2Mp
185: sonetOverheadChannel
186: digitalWrapperOverheadChannel
187: aal2
188: radioMAC
189: atmRadio
190: imt
191: mvl
192: reachDSL
193: frDlciEndPt
194: atmVciEndPt
195: opticalChannel
196: opticalTransport
197: propAtm
198: voiceOverCable
199: infiniband
200: teLink
201: q2931
202: virtualTg
203: sipTg
204: sipSig
205: docsCableUpstreamChannel
206: econet
207: pon155
208: pon622
209: bridge
210: linegroup
211: voiceEMFGD
212: voiceFGDEANA
213: voiceDID
214: mpegTransport
215: sixToFour
216: gtp
217: pdnEtherLoop1
218: pdnEtherLoop2
219: opticalChannelGroup
220: homepna
221: gfp
222: ciscoISLvlan
223: actelisMetaLOOP
224: fcipLink
225: rpr
226: qam
227: lmp
228: cblVectaStar
229: docsCableMCmtsDownstream
230: adsl2
231: macSecControlledIF
232: macSecUncontrolledIF
233: aviciOpticalEther
234: atmbond
235: voiceFGDOS
236: mocaVersion1
237: ieee80216WMAN
238: adsl2plus
239: dvbRcsMacLayer
240: dvbTdm
241: dvbRcsTdma
242: x86Laps
243: wwanPP
244: wwanPP2
245: voiceEBS
246: ifPwType
247: ilan
248: pip
249: aluELP
250: gpon
251: vdsl2
252: capwapDot11Profile
253: capwapDot11Bss
254: capwapWtpVirtualRadio
255: bits
256: docsCableUpstreamRfPort
257: cableDownstreamRfPort
258: vmwareVirtualNic
259: ieee802154
260: otnOdu
261: otnOtu
262: ifVfiType
263: g9981
264: g9982
265: g9983
266: aluEpon
267: aluEponOnu
268: aluEponPhysicalUni
269: aluEponLogicalLink
270: aluGponOnu
271: aluGponPhysicalUni
272: vmwareNicTeam
277: docsOfdmDownstream
278: docsOfdmaUpstream
279: gfast
280: sdci
281: xboxWireless
282: fastdsl
283: docsCableScte55d1FwdOob
284: docsCableScte55d1RetOob
285: docsCableScte55d2DsOob
286: docsCableScte55d2UsOob
287: docsCableNdf
288: docsCableNdr
289: ptm
290: ghn
291: otnOtsi
292: otnOtuc
293: otnOduc
294: otnOtsig
295: microwaveCarrierTermination
296: microwaveRadioLinkTerminal
297: ieee8021axDrni
298: ax25
299: ieee19061nanocom
300: cpri
- name: ifMtu
oid: 1.3.6.1.2.1.2.2.1.4
type: gauge
help: The size of the largest datagram which can be sent/received on the interface,
specified in octets - 1.3.6.1.2.1.2.2.1.4
indexes:
- labelname: ifIndex
type: gauge
lookups:
- labels:
- ifIndex
labelname: ifDescr
oid: 1.3.6.1.2.1.2.2.1.2
type: DisplayString
- labels: []
labelname: ifIndex
- name: ifSpeed
oid: 1.3.6.1.2.1.2.2.1.5
type: gauge
help: An estimate of the interface's current bandwidth in bits per second - 1.3.6.1.2.1.2.2.1.5
indexes:
- labelname: ifIndex
type: gauge
lookups:
- labels:
- ifIndex
labelname: ifDescr
oid: 1.3.6.1.2.1.2.2.1.2
type: DisplayString
- labels: []
labelname: ifIndex
- name: ifPhysAddress
oid: 1.3.6.1.2.1.2.2.1.6
type: PhysAddress48
help: The interface's address at the protocol layer immediately `below' the network
layer in the protocol stack - 1.3.6.1.2.1.2.2.1.6
indexes:
- labelname: ifIndex
type: gauge
lookups:
- labels:
- ifIndex
labelname: ifDescr
oid: 1.3.6.1.2.1.2.2.1.2
type: DisplayString
- labels: []
labelname: ifIndex
- name: ifAdminStatus
oid: 1.3.6.1.2.1.2.2.1.7
type: gauge
help: The desired state of the interface - 1.3.6.1.2.1.2.2.1.7
indexes:
- labelname: ifIndex
type: gauge
lookups:
- labels:
- ifIndex
labelname: ifDescr
oid: 1.3.6.1.2.1.2.2.1.2
type: DisplayString
- labels: []
labelname: ifIndex
enum_values:
1: up
2: down
3: testing
- name: ifOperStatus
oid: 1.3.6.1.2.1.2.2.1.8
type: gauge
help: The current operational state of the interface - 1.3.6.1.2.1.2.2.1.8
indexes:
- labelname: ifIndex
type: gauge
lookups:
- labels:
- ifIndex
labelname: ifDescr
oid: 1.3.6.1.2.1.2.2.1.2
type: DisplayString
- labels: []
labelname: ifIndex
enum_values:
1: up
2: down
3: testing
4: unknown
5: dormant
- name: ifLastChange
oid: 1.3.6.1.2.1.2.2.1.9
type: gauge
help: The value of sysUpTime at the time the interface entered its current operational
state - 1.3.6.1.2.1.2.2.1.9
indexes:
- labelname: ifIndex
type: gauge
lookups:
- labels:
- ifIndex
labelname: ifDescr
oid: 1.3.6.1.2.1.2.2.1.2
type: DisplayString
- labels: []
labelname: ifIndex
- name: ifInOctets
oid: 1.3.6.1.2.1.2.2.1.10
type: counter
help: The total number of octets received on the interface, including framing
characters. - 1.3.6.1.2.1.2.2.1.10
indexes:
- labelname: ifIndex
type: gauge
lookups:
- labels:
- ifIndex
labelname: ifDescr
oid: 1.3.6.1.2.1.2.2.1.2
type: DisplayString
- labels: []
labelname: ifIndex
- name: ifInUcastPkts
oid: 1.3.6.1.2.1.2.2.1.11
type: counter
help: The number of subnetwork-unicast packets delivered to a higher-layer protocol.
- 1.3.6.1.2.1.2.2.1.11
indexes:
- labelname: ifIndex
type: gauge
lookups:
- labels:
- ifIndex
labelname: ifDescr
oid: 1.3.6.1.2.1.2.2.1.2
type: DisplayString
- labels: []
labelname: ifIndex
- name: ifInNUcastPkts
oid: 1.3.6.1.2.1.2.2.1.12
type: counter
help: The number of non-unicast (i.e., subnetwork- broadcast or subnetwork-multicast)
packets delivered to a higher-layer protocol. - 1.3.6.1.2.1.2.2.1.12
indexes:
- labelname: ifIndex
type: gauge
lookups:
- labels:
- ifIndex
labelname: ifDescr
oid: 1.3.6.1.2.1.2.2.1.2
type: DisplayString
- labels: []
labelname: ifIndex
- name: ifInDiscards
oid: 1.3.6.1.2.1.2.2.1.13
type: counter
help: The number of inbound packets which were chosen to be discarded even though
no errors had been detected to prevent their being deliverable to a higher-layer
protocol - 1.3.6.1.2.1.2.2.1.13
indexes:
- labelname: ifIndex
type: gauge
lookups:
- labels:
- ifIndex
labelname: ifDescr
oid: 1.3.6.1.2.1.2.2.1.2
type: DisplayString
- labels: []
labelname: ifIndex
- name: ifInErrors
oid: 1.3.6.1.2.1.2.2.1.14
type: counter
help: The number of inbound packets that contained errors preventing them from
being deliverable to a higher-layer protocol. - 1.3.6.1.2.1.2.2.1.14
indexes:
- labelname: ifIndex
type: gauge
lookups:
- labels:
- ifIndex
labelname: ifDescr
oid: 1.3.6.1.2.1.2.2.1.2
type: DisplayString
- labels: []
labelname: ifIndex
- name: ifInUnknownProtos
oid: 1.3.6.1.2.1.2.2.1.15
type: counter
help: The number of packets received via the interface which were discarded because
of an unknown or unsupported protocol. - 1.3.6.1.2.1.2.2.1.15
indexes:
- labelname: ifIndex
type: gauge
lookups:
- labels:
- ifIndex
labelname: ifDescr
oid: 1.3.6.1.2.1.2.2.1.2
type: DisplayString
- labels: []
labelname: ifIndex
- name: ifOutOctets
oid: 1.3.6.1.2.1.2.2.1.16
type: counter
help: The total number of octets transmitted out of the interface, including framing
characters. - 1.3.6.1.2.1.2.2.1.16
indexes:
- labelname: ifIndex
type: gauge
lookups:
- labels:
- ifIndex
labelname: ifDescr
oid: 1.3.6.1.2.1.2.2.1.2
type: DisplayString
- labels: []
labelname: ifIndex
- name: ifOutUcastPkts
oid: 1.3.6.1.2.1.2.2.1.17
type: counter
help: The total number of packets that higher-level protocols requested be transmitted
to a subnetwork-unicast address, including those that were discarded or not
sent. - 1.3.6.1.2.1.2.2.1.17
indexes:
- labelname: ifIndex
type: gauge
lookups:
- labels:
- ifIndex
labelname: ifDescr
oid: 1.3.6.1.2.1.2.2.1.2
type: DisplayString
- labels: []
labelname: ifIndex
- name: ifOutNUcastPkts
oid: 1.3.6.1.2.1.2.2.1.18
type: counter
help: The total number of packets that higher-level protocols requested be transmitted
to a non- unicast (i.e., a subnetwork-broadcast or subnetwork-multicast) address,
including those that were discarded or not sent. - 1.3.6.1.2.1.2.2.1.18
indexes:
- labelname: ifIndex
type: gauge
lookups:
- labels:
- ifIndex
labelname: ifDescr
oid: 1.3.6.1.2.1.2.2.1.2
type: DisplayString
- labels: []
labelname: ifIndex
- name: ifOutDiscards
oid: 1.3.6.1.2.1.2.2.1.19
type: counter
help: The number of outbound packets which were chosen to be discarded even though
no errors had been detected to prevent their being transmitted - 1.3.6.1.2.1.2.2.1.19
indexes:
- labelname: ifIndex
type: gauge
lookups:
- labels:
- ifIndex
labelname: ifDescr
oid: 1.3.6.1.2.1.2.2.1.2
type: DisplayString
- labels: []
labelname: ifIndex
- name: ifOutErrors
oid: 1.3.6.1.2.1.2.2.1.20
type: counter
help: The number of outbound packets that could not be transmitted because of
errors. - 1.3.6.1.2.1.2.2.1.20
indexes:
- labelname: ifIndex
type: gauge
lookups:
- labels:
- ifIndex
labelname: ifDescr
oid: 1.3.6.1.2.1.2.2.1.2
type: DisplayString
- labels: []
labelname: ifIndex
- name: ifOutQLen
oid: 1.3.6.1.2.1.2.2.1.21
type: gauge
help: The length of the output packet queue (in packets). - 1.3.6.1.2.1.2.2.1.21
indexes:
- labelname: ifIndex
type: gauge
lookups:
- labels:
- ifIndex
labelname: ifDescr
oid: 1.3.6.1.2.1.2.2.1.2
type: DisplayString
- labels: []
labelname: ifIndex
- name: ifSpecific
oid: 1.3.6.1.2.1.2.2.1.22
type: OctetString
help: A reference to MIB definitions specific to the particular media being used
to realize the interface - 1.3.6.1.2.1.2.2.1.22
indexes:
- labelname: ifIndex
type: gauge
lookups:
- labels:
- ifIndex
labelname: ifDescr
oid: 1.3.6.1.2.1.2.2.1.2
type: DisplayString
- labels: []
labelname: ifIndex
- name: upsIdentManufacturer
oid: 1.3.6.1.2.1.33.1.1.1
type: DisplayString
help: The name of the UPS manufacturer. - 1.3.6.1.2.1.33.1.1.1
- name: upsIdentModel
oid: 1.3.6.1.2.1.33.1.1.2
type: DisplayString
help: The UPS Model designation. - 1.3.6.1.2.1.33.1.1.2
- name: upsIdentUPSSoftwareVersion
oid: 1.3.6.1.2.1.33.1.1.3
type: DisplayString
help: The UPS firmware/software version(s) - 1.3.6.1.2.1.33.1.1.3
- name: upsIdentAgentSoftwareVersion
oid: 1.3.6.1.2.1.33.1.1.4
type: DisplayString
help: The UPS agent software version - 1.3.6.1.2.1.33.1.1.4
- name: upsIdentName
oid: 1.3.6.1.2.1.33.1.1.5
type: DisplayString
help: A string identifying the UPS - 1.3.6.1.2.1.33.1.1.5
- name: upsIdentAttachedDevices
oid: 1.3.6.1.2.1.33.1.1.6
type: DisplayString
help: A string identifying the devices attached to the output(s) of the UPS -
1.3.6.1.2.1.33.1.1.6
- name: upsBatteryStatus
oid: 1.3.6.1.2.1.33.1.2.1
type: EnumAsStateSet
help: The indication of the capacity remaining in the UPS system's batteries -
1.3.6.1.2.1.33.1.2.1
enum_values:
1: unknown
2: batteryNormal
3: batteryLow
4: batteryDepleted
- name: upsSecondsOnBattery
oid: 1.3.6.1.2.1.33.1.2.2
type: gauge
help: If the unit is on battery power, the elapsed time since the UPS last switched
to battery power, or the time since the network management subsystem was last
restarted, whichever is less - 1.3.6.1.2.1.33.1.2.2
- name: upsEstimatedMinutesRemaining
oid: 1.3.6.1.2.1.33.1.2.3
type: gauge
help: An estimate of the time to battery charge depletion under the present load
conditions if the utility power is off and remains off, or if it were to be
lost and remain off. - 1.3.6.1.2.1.33.1.2.3
- name: upsEstimatedChargeRemaining
oid: 1.3.6.1.2.1.33.1.2.4
type: gauge
help: An estimate of the battery charge remaining expressed as a percent of full
charge. - 1.3.6.1.2.1.33.1.2.4
- name: upsBatteryVoltage
oid: 1.3.6.1.2.1.33.1.2.5
type: gauge
help: The magnitude of the present battery voltage. - 1.3.6.1.2.1.33.1.2.5
- name: upsBatteryCurrent
oid: 1.3.6.1.2.1.33.1.2.6
type: gauge
help: The present battery current. - 1.3.6.1.2.1.33.1.2.6
- name: upsBatteryTemperature
oid: 1.3.6.1.2.1.33.1.2.7
type: gauge
help: The ambient temperature at or near the UPS Battery casing. - 1.3.6.1.2.1.33.1.2.7
- name: upsInputLineBads
oid: 1.3.6.1.2.1.33.1.3.1
type: counter
help: A count of the number of times the input entered an out-of-tolerance condition
as defined by the manufacturer - 1.3.6.1.2.1.33.1.3.1
- name: upsInputNumLines
oid: 1.3.6.1.2.1.33.1.3.2
type: gauge
help: The number of input lines utilized in this device - 1.3.6.1.2.1.33.1.3.2
- name: upsInputLineIndex
oid: 1.3.6.1.2.1.33.1.3.3.1.1
type: gauge
help: The input line identifier. - 1.3.6.1.2.1.33.1.3.3.1.1
indexes:
- labelname: upsInputLineIndex
type: gauge
- name: upsInputFrequency
oid: 1.3.6.1.2.1.33.1.3.3.1.2
type: gauge
help: The present input frequency. - 1.3.6.1.2.1.33.1.3.3.1.2
indexes:
- labelname: upsInputLineIndex
type: gauge
- name: upsInputVoltage
oid: 1.3.6.1.2.1.33.1.3.3.1.3
type: gauge
help: The magnitude of the present input voltage. - 1.3.6.1.2.1.33.1.3.3.1.3
indexes:
- labelname: upsInputLineIndex
type: gauge
- name: upsInputCurrent
oid: 1.3.6.1.2.1.33.1.3.3.1.4
type: gauge
help: The magnitude of the present input current. - 1.3.6.1.2.1.33.1.3.3.1.4
indexes:
- labelname: upsInputLineIndex
type: gauge
- name: upsInputTruePower
oid: 1.3.6.1.2.1.33.1.3.3.1.5
type: gauge
help: The magnitude of the present input true power. - 1.3.6.1.2.1.33.1.3.3.1.5
indexes:
- labelname: upsInputLineIndex
type: gauge
- name: upsOutputSource
oid: 1.3.6.1.2.1.33.1.4.1
type: EnumAsStateSet
help: The present source of output power - 1.3.6.1.2.1.33.1.4.1
enum_values:
1: other
2: none
3: normal
4: bypass
5: battery
6: booster
7: reducer
- name: upsOutputFrequency
oid: 1.3.6.1.2.1.33.1.4.2
type: gauge
help: The present output frequency. - 1.3.6.1.2.1.33.1.4.2
- name: upsOutputNumLines
oid: 1.3.6.1.2.1.33.1.4.3
type: gauge
help: The number of output lines utilized in this device - 1.3.6.1.2.1.33.1.4.3
- name: upsOutputLineIndex
oid: 1.3.6.1.2.1.33.1.4.4.1.1
type: gauge
help: The output line identifier. - 1.3.6.1.2.1.33.1.4.4.1.1
indexes:
- labelname: upsOutputLineIndex
type: gauge
- name: upsOutputVoltage
oid: 1.3.6.1.2.1.33.1.4.4.1.2
type: gauge
help: The present output voltage. - 1.3.6.1.2.1.33.1.4.4.1.2
indexes:
- labelname: upsOutputLineIndex
type: gauge
- name: upsOutputCurrent
oid: 1.3.6.1.2.1.33.1.4.4.1.3
type: gauge
help: The present output current. - 1.3.6.1.2.1.33.1.4.4.1.3
indexes:
- labelname: upsOutputLineIndex
type: gauge
- name: upsOutputPower
oid: 1.3.6.1.2.1.33.1.4.4.1.4
type: gauge
help: The present output true power. - 1.3.6.1.2.1.33.1.4.4.1.4
indexes:
- labelname: upsOutputLineIndex
type: gauge
- name: upsOutputPercentLoad
oid: 1.3.6.1.2.1.33.1.4.4.1.5
type: gauge
help: The percentage of the UPS power capacity presently being used on this output
line, i.e., the greater of the percent load of true power capacity and the percent
load of VA. - 1.3.6.1.2.1.33.1.4.4.1.5
indexes:
- labelname: upsOutputLineIndex
type: gauge
- name: upsBypassFrequency
oid: 1.3.6.1.2.1.33.1.5.1
type: gauge
help: The present bypass frequency. - 1.3.6.1.2.1.33.1.5.1
- name: upsBypassNumLines
oid: 1.3.6.1.2.1.33.1.5.2
type: gauge
help: The number of bypass lines utilized in this device - 1.3.6.1.2.1.33.1.5.2
- name: upsBypassLineIndex
oid: 1.3.6.1.2.1.33.1.5.3.1.1
type: gauge
help: The bypass line identifier. - 1.3.6.1.2.1.33.1.5.3.1.1
indexes:
- labelname: upsBypassLineIndex
type: gauge
- name: upsBypassVoltage
oid: 1.3.6.1.2.1.33.1.5.3.1.2
type: gauge
help: The present bypass voltage. - 1.3.6.1.2.1.33.1.5.3.1.2
indexes:
- labelname: upsBypassLineIndex
type: gauge
- name: upsBypassCurrent
oid: 1.3.6.1.2.1.33.1.5.3.1.3
type: gauge
help: The present bypass current. - 1.3.6.1.2.1.33.1.5.3.1.3
indexes:
- labelname: upsBypassLineIndex
type: gauge
- name: upsBypassPower
oid: 1.3.6.1.2.1.33.1.5.3.1.4
type: gauge
help: The present true power conveyed by the bypass. - 1.3.6.1.2.1.33.1.5.3.1.4
indexes:
- labelname: upsBypassLineIndex
type: gauge
- name: upsAlarmsPresent
oid: 1.3.6.1.2.1.33.1.6.1
type: gauge
help: The present number of active alarm conditions. - 1.3.6.1.2.1.33.1.6.1
- name: upsAlarmId
oid: 1.3.6.1.2.1.33.1.6.2.1.1
type: gauge
help: A unique identifier for an alarm condition - 1.3.6.1.2.1.33.1.6.2.1.1
indexes:
- labelname: upsAlarmId
type: gauge
- name: upsAlarmDescr
oid: 1.3.6.1.2.1.33.1.6.2.1.2
type: OctetString
help: A reference to an alarm description object - 1.3.6.1.2.1.33.1.6.2.1.2
indexes:
- labelname: upsAlarmId
type: gauge
- name: upsAlarmTime
oid: 1.3.6.1.2.1.33.1.6.2.1.3
type: gauge
help: The value of sysUpTime when the alarm condition was detected - 1.3.6.1.2.1.33.1.6.2.1.3
indexes:
- labelname: upsAlarmId
type: gauge
- name: upsTestId
oid: 1.3.6.1.2.1.33.1.7.1
type: OctetString
help: The test is named by an OBJECT IDENTIFIER which allows a standard mechanism
for the initiation of tests, including the well known tests identified in this
document as well as those introduced by a particular implementation, i.e., as
documented in the private enterprise MIB definition for the device - 1.3.6.1.2.1.33.1.7.1
- name: upsTestSpinLock
oid: 1.3.6.1.2.1.33.1.7.2
type: gauge
help: A spin lock on the test subsystem - 1.3.6.1.2.1.33.1.7.2
- name: upsTestResultsSummary
oid: 1.3.6.1.2.1.33.1.7.3
type: EnumAsStateSet
help: The results of the current or last UPS diagnostics test performed - 1.3.6.1.2.1.33.1.7.3
enum_values:
1: donePass
2: doneWarning
3: doneError
4: aborted
5: inProgress
6: noTestsInitiated
- name: upsTestResultsDetail
oid: 1.3.6.1.2.1.33.1.7.4
type: DisplayString
help: Additional information about upsTestResultsSummary - 1.3.6.1.2.1.33.1.7.4
- name: upsTestStartTime
oid: 1.3.6.1.2.1.33.1.7.5
type: gauge
help: The value of sysUpTime at the time the test in progress was initiated, or,
if no test is in progress, the time the previous test was initiated - 1.3.6.1.2.1.33.1.7.5
- name: upsTestElapsedTime
oid: 1.3.6.1.2.1.33.1.7.6
type: gauge
help: The amount of time, in TimeTicks, since the test in progress was initiated,
or, if no test is in progress, the previous test took to complete - 1.3.6.1.2.1.33.1.7.6
- name: upsShutdownType
oid: 1.3.6.1.2.1.33.1.8.1
type: EnumAsStateSet
help: This object determines the nature of the action to be taken at the time
when the countdown of the upsShutdownAfterDelay and upsRebootWithDuration objects
reaches zero - 1.3.6.1.2.1.33.1.8.1
enum_values:
1: output
2: system
- name: upsShutdownAfterDelay
oid: 1.3.6.1.2.1.33.1.8.2
type: gauge
help: Setting this object will shutdown (i.e., turn off) either the UPS output
or the UPS system (as determined by the value of upsShutdownType at the time
of shutdown) after the indicated number of seconds, or less if the UPS batteries
become depleted - 1.3.6.1.2.1.33.1.8.2
- name: upsStartupAfterDelay
oid: 1.3.6.1.2.1.33.1.8.3
type: gauge
help: Setting this object will start the output after the indicated number of
seconds, including starting the UPS, if necessary - 1.3.6.1.2.1.33.1.8.3
- name: upsRebootWithDuration
oid: 1.3.6.1.2.1.33.1.8.4
type: gauge
help: Setting this object will immediately shutdown (i.e., turn off) either the
UPS output or the UPS system (as determined by the value of upsShutdownType
at the time of shutdown) for a period equal to the indicated number of seconds,
after which time the output will be started, including starting the UPS, if
necessary - 1.3.6.1.2.1.33.1.8.4
- name: upsAutoRestart
oid: 1.3.6.1.2.1.33.1.8.5
type: EnumAsStateSet
help: Setting this object to 'on' will cause the UPS system to restart after a
shutdown if the shutdown occurred during a power loss as a result of either
a upsShutdownAfterDelay or an internal battery depleted condition - 1.3.6.1.2.1.33.1.8.5
enum_values:
1: "on"
2: "off"
- name: upsConfigInputVoltage
oid: 1.3.6.1.2.1.33.1.9.1
type: gauge
help: The magnitude of the nominal input voltage - 1.3.6.1.2.1.33.1.9.1
- name: upsConfigInputFreq
oid: 1.3.6.1.2.1.33.1.9.2
type: gauge
help: The nominal input frequency - 1.3.6.1.2.1.33.1.9.2
- name: upsConfigOutputVoltage
oid: 1.3.6.1.2.1.33.1.9.3
type: gauge
help: The magnitude of the nominal output voltage - 1.3.6.1.2.1.33.1.9.3
- name: upsConfigOutputFreq
oid: 1.3.6.1.2.1.33.1.9.4
type: gauge
help: The nominal output frequency - 1.3.6.1.2.1.33.1.9.4
- name: upsConfigOutputVA
oid: 1.3.6.1.2.1.33.1.9.5
type: gauge
help: The magnitude of the nominal Volt-Amp rating. - 1.3.6.1.2.1.33.1.9.5
- name: upsConfigOutputPower
oid: 1.3.6.1.2.1.33.1.9.6
type: gauge
help: The magnitude of the nominal true power rating. - 1.3.6.1.2.1.33.1.9.6
- name: upsConfigLowBattTime
oid: 1.3.6.1.2.1.33.1.9.7
type: gauge
help: The value of upsEstimatedMinutesRemaining at which a lowBattery condition
is declared - 1.3.6.1.2.1.33.1.9.7
- name: upsConfigAudibleStatus
oid: 1.3.6.1.2.1.33.1.9.8
type: EnumAsStateSet
help: The requested state of the audible alarm - 1.3.6.1.2.1.33.1.9.8
enum_values:
1: disabled
2: enabled
3: muted
- name: upsConfigLowVoltageTransferPoint
oid: 1.3.6.1.2.1.33.1.9.9
type: gauge
help: The minimum input line voltage allowed before the UPS system transfers to
battery backup. - 1.3.6.1.2.1.33.1.9.9
- name: upsConfigHighVoltageTransferPoint
oid: 1.3.6.1.2.1.33.1.9.10
type: gauge
help: The maximum line voltage allowed before the UPS system transfers to battery
backup. - 1.3.6.1.2.1.33.1.9.10
version: 1