epson_beamer: get: - 1.3.6.1.4.1.1248.4.1.1.1.1.0 - 1.3.6.1.4.1.1248.4.1.1.2.7.0 - 1.3.6.1.4.1.1248.4.1.1.1.8.0 - 1.3.6.1.4.1.1248.4.1.1.2.2.0 - 1.3.6.1.4.1.1248.4.1.1.1.9.0 - 1.3.6.1.4.1.1248.4.1.1.2.1.0 metrics: - name: EpsonLampHours oid: 1.3.6.1.4.1.1248.4.1.1.1.1.0 type: counter - name: EpsonName oid: 1.3.6.1.4.1.1248.4.1.1.2.7.0 type: DisplayString - name: EpsonFirmwareVersion oid: 1.3.6.1.4.1.1248.4.1.1.1.8.0 type: DisplayString - name: EpsonInputSource oid: 1.3.6.1.4.1.1248.4.1.1.2.2.0 type: DisplayString - name: EpsonProjectorStatus oid: 1.3.6.1.4.1.1248.4.1.1.1.9.0 type: DisplayString # "01 0000 0000 T1": "Standby OK OK" # "01 0000 0001 T1": "Standby OK Lamp ON failure" # "01 0000 0002 T1": "Standby OK Lamp lid" # "01 0000 0003 T1": "Standby OK Lamp burnout (ON, then OFF)" # "01 0000 0004 T1": "Standby OK Fan" - name: EpsonPower oid: 1.3.6.1.4.1.1248.4.1.1.2.1.0 help: on or off type: gauge printer_mib: walk: - 1.3.6.1.2.1.25.3.5.1.1 - 1.3.6.1.2.1.43.11.1.1.5 - 1.3.6.1.2.1.43.11.1.1.6 - 1.3.6.1.2.1.43.11.1.1.8 - 1.3.6.1.2.1.43.11.1.1.9 - 1.3.6.1.2.1.43.5.1.1.13 - 1.3.6.1.2.1.43.5.1.1.16 - 1.3.6.1.2.1.43.5.1.1.17 - 1.3.6.1.2.1.43.5.1.1.18 - 1.3.6.1.2.1.43.5.1.1.19 - 1.3.6.1.2.1.43.5.1.1.3 - 1.3.6.1.2.1.43.6.1.1.3 get: - 1.3.6.1.2.1.1.3.0 metrics: - name: sysUpTime oid: 1.3.6.1.2.1.1.3 type: gauge help: The time (in hundredths of a second) since the network management portion of the system was last re-initialized. - 1.3.6.1.2.1.1.3 - name: hrPrinterStatus oid: 1.3.6.1.2.1.25.3.5.1.1 type: EnumAsStateSet help: The current status of this printer device. - 1.3.6.1.2.1.25.3.5.1.1 indexes: - labelname: hrDeviceIndex type: gauge enum_values: 1: other 2: unknown 3: idle 4: printing 5: warmup - name: prtMarkerSuppliesType oid: 1.3.6.1.2.1.43.11.1.1.5 type: gauge help: The type of this supply. - 1.3.6.1.2.1.43.11.1.1.5 indexes: - labelname: hrDeviceIndex type: gauge - labelname: prtMarkerSuppliesIndex type: gauge lookups: - labels: - hrDeviceIndex - prtMarkerSuppliesIndex labelname: prtMarkerSuppliesType oid: 1.3.6.1.2.1.43.11.1.1.5 type: gauge enum_values: 1: other 2: unknown 3: toner 4: wasteToner 5: ink 6: inkCartridge 7: inkRibbon 8: wasteInk 9: opc 10: developer 11: fuserOil 12: solidWax 13: ribbonWax 14: wasteWax 15: fuser 16: coronaWire 17: fuserOilWick 18: cleanerUnit 19: fuserCleaningPad 20: transferUnit 21: tonerCartridge 22: fuserOiler 23: water 24: wasteWater 25: glueWaterAdditive 26: wastePaper 27: bindingSupply 28: bandingSupply 29: stitchingWire 30: shrinkWrap 31: paperWrap 32: staples 33: inserts 34: covers 35: matteToner 36: matteInk - name: prtMarkerSuppliesDescription oid: 1.3.6.1.2.1.43.11.1.1.6 type: DisplayString help: The description of this supply container/receptacle in the localization specified by prtGeneralCurrentLocalization. - 1.3.6.1.2.1.43.11.1.1.6 indexes: - labelname: hrDeviceIndex type: gauge - labelname: prtMarkerSuppliesIndex type: gauge lookups: - labels: - hrDeviceIndex - prtMarkerSuppliesIndex labelname: prtMarkerSuppliesType oid: 1.3.6.1.2.1.43.11.1.1.5 type: gauge - name: prtMarkerSuppliesMaxCapacity oid: 1.3.6.1.2.1.43.11.1.1.8 type: gauge help: The maximum capacity of this supply container/receptacle expressed in prtMarkerSuppliesSupplyUnit - 1.3.6.1.2.1.43.11.1.1.8 indexes: - labelname: hrDeviceIndex type: gauge - labelname: prtMarkerSuppliesIndex type: gauge lookups: - labels: - hrDeviceIndex - prtMarkerSuppliesIndex labelname: prtMarkerSuppliesType oid: 1.3.6.1.2.1.43.11.1.1.5 type: gauge - name: prtMarkerSuppliesLevel oid: 1.3.6.1.2.1.43.11.1.1.9 type: gauge help: The current level if this supply is a container; the remaining space if this supply is a receptacle - 1.3.6.1.2.1.43.11.1.1.9 indexes: - labelname: hrDeviceIndex type: gauge - labelname: prtMarkerSuppliesIndex type: gauge lookups: - labels: - hrDeviceIndex - prtMarkerSuppliesIndex labelname: prtMarkerSuppliesType oid: 1.3.6.1.2.1.43.11.1.1.5 type: gauge - name: prtConsoleDisable oid: 1.3.6.1.2.1.43.5.1.1.13 type: EnumAsStateSet help: This value indicates how input is (or is not) accepted from the operator console - 1.3.6.1.2.1.43.5.1.1.13 indexes: - labelname: hrDeviceIndex type: gauge enum_values: 3: enabled 4: disabled - name: prtGeneralPrinterName oid: 1.3.6.1.2.1.43.5.1.1.16 type: DisplayString help: An administrator-specified name for this printer - 1.3.6.1.2.1.43.5.1.1.16 indexes: - labelname: hrDeviceIndex type: gauge - name: prtGeneralSerialNumber oid: 1.3.6.1.2.1.43.5.1.1.17 type: DisplayString help: A recorded serial number for this device that indexes some type device catalog or inventory - 1.3.6.1.2.1.43.5.1.1.17 indexes: - labelname: hrDeviceIndex type: gauge - name: prtAlertCriticalEvents oid: 1.3.6.1.2.1.43.5.1.1.18 type: counter help: A running counter of the number of critical alert events that have been recorded in the alert table - 1.3.6.1.2.1.43.5.1.1.18 indexes: - labelname: hrDeviceIndex type: gauge - name: prtAlertAllEvents oid: 1.3.6.1.2.1.43.5.1.1.19 type: counter help: A running counter of the total number of alert event entries (critical and non-critical) that have been recorded in the alert table - 1.3.6.1.2.1.43.5.1.1.19 indexes: - labelname: hrDeviceIndex type: gauge - name: prtGeneralReset oid: 1.3.6.1.2.1.43.5.1.1.3 type: EnumAsStateSet help: Setting this value to 'powerCycleReset', 'resetToNVRAM', or 'resetToFactoryDefaults' will result in the resetting of the printer - 1.3.6.1.2.1.43.5.1.1.3 indexes: - labelname: hrDeviceIndex type: gauge enum_values: 3: notResetting 4: powerCycleReset 5: resetToNVRAM 6: resetToFactoryDefaults - name: prtCoverStatus oid: 1.3.6.1.2.1.43.6.1.1.3 type: EnumAsStateSet help: The status of this cover sub-unit. - 1.3.6.1.2.1.43.6.1.1.3 indexes: - labelname: hrDeviceIndex type: gauge - labelname: prtCoverIndex type: gauge enum_values: 1: other 2: unknown 3: coverOpen 4: coverClosed 5: interlockOpen 6: interlockClosed rfc1628_ups: walk: - 1.3.6.1.2.1.2 - 1.3.6.1.2.1.33.1.1 - 1.3.6.1.2.1.33.1.2 - 1.3.6.1.2.1.33.1.3 - 1.3.6.1.2.1.33.1.4 - 1.3.6.1.2.1.33.1.5 - 1.3.6.1.2.1.33.1.6 - 1.3.6.1.2.1.33.1.7 - 1.3.6.1.2.1.33.1.8 - 1.3.6.1.2.1.33.1.9 get: - 1.3.6.1.2.1.1.3.0 metrics: - name: sysUpTime oid: 1.3.6.1.2.1.1.3 type: gauge help: The time (in hundredths of a second) since the network management portion of the system was last re-initialized. - 1.3.6.1.2.1.1.3 - name: ifNumber oid: 1.3.6.1.2.1.2.1 type: gauge help: The number of network interfaces (regardless of their current state) present on this system. - 1.3.6.1.2.1.2.1 - name: ifIndex oid: 1.3.6.1.2.1.2.2.1.1 type: gauge help: A unique value for each interface - 1.3.6.1.2.1.2.2.1.1 indexes: - labelname: ifIndex type: gauge lookups: - labels: - ifIndex labelname: ifDescr oid: 1.3.6.1.2.1.2.2.1.2 type: DisplayString - labels: [] labelname: ifIndex - name: ifDescr oid: 1.3.6.1.2.1.2.2.1.2 type: DisplayString help: A textual string containing information about the interface - 1.3.6.1.2.1.2.2.1.2 indexes: - labelname: ifIndex type: gauge lookups: - labels: - ifIndex labelname: ifDescr oid: 1.3.6.1.2.1.2.2.1.2 type: DisplayString - labels: [] labelname: ifIndex - name: ifType oid: 1.3.6.1.2.1.2.2.1.3 type: EnumAsInfo help: The type of interface - 1.3.6.1.2.1.2.2.1.3 indexes: - labelname: ifIndex type: gauge lookups: - labels: - ifIndex labelname: ifDescr oid: 1.3.6.1.2.1.2.2.1.2 type: DisplayString - labels: [] labelname: ifIndex enum_values: 1: other 2: regular1822 3: hdh1822 4: ddnX25 5: rfc877x25 6: ethernetCsmacd 7: iso88023Csmacd 8: iso88024TokenBus 9: iso88025TokenRing 10: iso88026Man 11: starLan 12: proteon10Mbit 13: proteon80Mbit 14: hyperchannel 15: fddi 16: lapb 17: sdlc 18: ds1 19: e1 20: basicISDN 21: primaryISDN 22: propPointToPointSerial 23: ppp 24: softwareLoopback 25: eon 26: ethernet3Mbit 27: nsip 28: slip 29: ultra 30: ds3 31: sip 32: frameRelay 33: rs232 34: para 35: arcnet 36: arcnetPlus 37: atm 38: miox25 39: sonet 40: x25ple 41: iso88022llc 42: localTalk 43: smdsDxi 44: frameRelayService 45: v35 46: hssi 47: hippi 48: modem 49: aal5 50: sonetPath 51: sonetVT 52: smdsIcip 53: propVirtual 54: propMultiplexor 55: ieee80212 56: fibreChannel 57: hippiInterface 58: frameRelayInterconnect 59: aflane8023 60: aflane8025 61: cctEmul 62: fastEther 63: isdn 64: v11 65: v36 66: g703at64k 67: g703at2mb 68: qllc 69: fastEtherFX 70: channel 71: ieee80211 72: ibm370parChan 73: escon 74: dlsw 75: isdns 76: isdnu 77: lapd 78: ipSwitch 79: rsrb 80: atmLogical 81: ds0 82: ds0Bundle 83: bsc 84: async 85: cnr 86: iso88025Dtr 87: eplrs 88: arap 89: propCnls 90: hostPad 91: termPad 92: frameRelayMPI 93: x213 94: adsl 95: radsl 96: sdsl 97: vdsl 98: iso88025CRFPInt 99: myrinet 100: voiceEM 101: voiceFXO 102: voiceFXS 103: voiceEncap 104: voiceOverIp 105: atmDxi 106: atmFuni 107: atmIma 108: pppMultilinkBundle 109: ipOverCdlc 110: ipOverClaw 111: stackToStack 112: virtualIpAddress 113: mpc 114: ipOverAtm 115: iso88025Fiber 116: tdlc 117: gigabitEthernet 118: hdlc 119: lapf 120: v37 121: x25mlp 122: x25huntGroup 123: transpHdlc 124: interleave 125: fast 126: ip 127: docsCableMaclayer 128: docsCableDownstream 129: docsCableUpstream 130: a12MppSwitch 131: tunnel 132: coffee 133: ces 134: atmSubInterface 135: l2vlan 136: l3ipvlan 137: l3ipxvlan 138: digitalPowerline 139: mediaMailOverIp 140: dtm 141: dcn 142: ipForward 143: msdsl 144: ieee1394 145: if-gsn 146: dvbRccMacLayer 147: dvbRccDownstream 148: dvbRccUpstream 149: atmVirtual 150: mplsTunnel 151: srp 152: voiceOverAtm 153: voiceOverFrameRelay 154: idsl 155: compositeLink 156: ss7SigLink 157: propWirelessP2P 158: frForward 159: rfc1483 160: usb 161: ieee8023adLag 162: bgppolicyaccounting 163: frf16MfrBundle 164: h323Gatekeeper 165: h323Proxy 166: mpls 167: mfSigLink 168: hdsl2 169: shdsl 170: ds1FDL 171: pos 172: dvbAsiIn 173: dvbAsiOut 174: plc 175: nfas 176: tr008 177: gr303RDT 178: gr303IDT 179: isup 180: propDocsWirelessMaclayer 181: propDocsWirelessDownstream 182: propDocsWirelessUpstream 183: hiperlan2 184: propBWAp2Mp 185: sonetOverheadChannel 186: digitalWrapperOverheadChannel 187: aal2 188: radioMAC 189: atmRadio 190: imt 191: mvl 192: reachDSL 193: frDlciEndPt 194: atmVciEndPt 195: opticalChannel 196: opticalTransport 197: propAtm 198: voiceOverCable 199: infiniband 200: teLink 201: q2931 202: virtualTg 203: sipTg 204: sipSig 205: docsCableUpstreamChannel 206: econet 207: pon155 208: pon622 209: bridge 210: linegroup 211: voiceEMFGD 212: voiceFGDEANA 213: voiceDID 214: mpegTransport 215: sixToFour 216: gtp 217: pdnEtherLoop1 218: pdnEtherLoop2 219: opticalChannelGroup 220: homepna 221: gfp 222: ciscoISLvlan 223: actelisMetaLOOP 224: fcipLink 225: rpr 226: qam 227: lmp 228: cblVectaStar 229: docsCableMCmtsDownstream 230: adsl2 231: macSecControlledIF 232: macSecUncontrolledIF 233: aviciOpticalEther 234: atmbond 235: voiceFGDOS 236: mocaVersion1 237: ieee80216WMAN 238: adsl2plus 239: dvbRcsMacLayer 240: dvbTdm 241: dvbRcsTdma 242: x86Laps 243: wwanPP 244: wwanPP2 245: voiceEBS 246: ifPwType 247: ilan 248: pip 249: aluELP 250: gpon 251: vdsl2 252: capwapDot11Profile 253: capwapDot11Bss 254: capwapWtpVirtualRadio 255: bits 256: docsCableUpstreamRfPort 257: cableDownstreamRfPort 258: vmwareVirtualNic 259: ieee802154 260: otnOdu 261: otnOtu 262: ifVfiType 263: g9981 264: g9982 265: g9983 266: aluEpon 267: aluEponOnu 268: aluEponPhysicalUni 269: aluEponLogicalLink 270: aluGponOnu 271: aluGponPhysicalUni 272: vmwareNicTeam 277: docsOfdmDownstream 278: docsOfdmaUpstream 279: gfast 280: sdci 281: xboxWireless 282: fastdsl 283: docsCableScte55d1FwdOob 284: docsCableScte55d1RetOob 285: docsCableScte55d2DsOob 286: docsCableScte55d2UsOob 287: docsCableNdf 288: docsCableNdr 289: ptm 290: ghn 291: otnOtsi 292: otnOtuc 293: otnOduc 294: otnOtsig 295: microwaveCarrierTermination 296: microwaveRadioLinkTerminal 297: ieee8021axDrni 298: ax25 299: ieee19061nanocom 300: cpri - name: ifMtu oid: 1.3.6.1.2.1.2.2.1.4 type: gauge help: The size of the largest datagram which can be sent/received on the interface, specified in octets - 1.3.6.1.2.1.2.2.1.4 indexes: - labelname: ifIndex type: gauge lookups: - labels: - ifIndex labelname: ifDescr oid: 1.3.6.1.2.1.2.2.1.2 type: DisplayString - labels: [] labelname: ifIndex - name: ifSpeed oid: 1.3.6.1.2.1.2.2.1.5 type: gauge help: An estimate of the interface's current bandwidth in bits per second - 1.3.6.1.2.1.2.2.1.5 indexes: - labelname: ifIndex type: gauge lookups: - labels: - ifIndex labelname: ifDescr oid: 1.3.6.1.2.1.2.2.1.2 type: DisplayString - labels: [] labelname: ifIndex - name: ifPhysAddress oid: 1.3.6.1.2.1.2.2.1.6 type: PhysAddress48 help: The interface's address at the protocol layer immediately `below' the network layer in the protocol stack - 1.3.6.1.2.1.2.2.1.6 indexes: - labelname: ifIndex type: gauge lookups: - labels: - ifIndex labelname: ifDescr oid: 1.3.6.1.2.1.2.2.1.2 type: DisplayString - labels: [] labelname: ifIndex - name: ifAdminStatus oid: 1.3.6.1.2.1.2.2.1.7 type: gauge help: The desired state of the interface - 1.3.6.1.2.1.2.2.1.7 indexes: - labelname: ifIndex type: gauge lookups: - labels: - ifIndex labelname: ifDescr oid: 1.3.6.1.2.1.2.2.1.2 type: DisplayString - labels: [] labelname: ifIndex enum_values: 1: up 2: down 3: testing - name: ifOperStatus oid: 1.3.6.1.2.1.2.2.1.8 type: gauge help: The current operational state of the interface - 1.3.6.1.2.1.2.2.1.8 indexes: - labelname: ifIndex type: gauge lookups: - labels: - ifIndex labelname: ifDescr oid: 1.3.6.1.2.1.2.2.1.2 type: DisplayString - labels: [] labelname: ifIndex enum_values: 1: up 2: down 3: testing 4: unknown 5: dormant - name: ifLastChange oid: 1.3.6.1.2.1.2.2.1.9 type: gauge help: The value of sysUpTime at the time the interface entered its current operational state - 1.3.6.1.2.1.2.2.1.9 indexes: - labelname: ifIndex type: gauge lookups: - labels: - ifIndex labelname: ifDescr oid: 1.3.6.1.2.1.2.2.1.2 type: DisplayString - labels: [] labelname: ifIndex - name: ifInOctets oid: 1.3.6.1.2.1.2.2.1.10 type: counter help: The total number of octets received on the interface, including framing characters. - 1.3.6.1.2.1.2.2.1.10 indexes: - labelname: ifIndex type: gauge lookups: - labels: - ifIndex labelname: ifDescr oid: 1.3.6.1.2.1.2.2.1.2 type: DisplayString - labels: [] labelname: ifIndex - name: ifInUcastPkts oid: 1.3.6.1.2.1.2.2.1.11 type: counter help: The number of subnetwork-unicast packets delivered to a higher-layer protocol. - 1.3.6.1.2.1.2.2.1.11 indexes: - labelname: ifIndex type: gauge lookups: - labels: - ifIndex labelname: ifDescr oid: 1.3.6.1.2.1.2.2.1.2 type: DisplayString - labels: [] labelname: ifIndex - name: ifInNUcastPkts oid: 1.3.6.1.2.1.2.2.1.12 type: counter help: The number of non-unicast (i.e., subnetwork- broadcast or subnetwork-multicast) packets delivered to a higher-layer protocol. - 1.3.6.1.2.1.2.2.1.12 indexes: - labelname: ifIndex type: gauge lookups: - labels: - ifIndex labelname: ifDescr oid: 1.3.6.1.2.1.2.2.1.2 type: DisplayString - labels: [] labelname: ifIndex - name: ifInDiscards oid: 1.3.6.1.2.1.2.2.1.13 type: counter help: The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol - 1.3.6.1.2.1.2.2.1.13 indexes: - labelname: ifIndex type: gauge lookups: - labels: - ifIndex labelname: ifDescr oid: 1.3.6.1.2.1.2.2.1.2 type: DisplayString - labels: [] labelname: ifIndex - name: ifInErrors oid: 1.3.6.1.2.1.2.2.1.14 type: counter help: The number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. - 1.3.6.1.2.1.2.2.1.14 indexes: - labelname: ifIndex type: gauge lookups: - labels: - ifIndex labelname: ifDescr oid: 1.3.6.1.2.1.2.2.1.2 type: DisplayString - labels: [] labelname: ifIndex - name: ifInUnknownProtos oid: 1.3.6.1.2.1.2.2.1.15 type: counter help: The number of packets received via the interface which were discarded because of an unknown or unsupported protocol. - 1.3.6.1.2.1.2.2.1.15 indexes: - labelname: ifIndex type: gauge lookups: - labels: - ifIndex labelname: ifDescr oid: 1.3.6.1.2.1.2.2.1.2 type: DisplayString - labels: [] labelname: ifIndex - name: ifOutOctets oid: 1.3.6.1.2.1.2.2.1.16 type: counter help: The total number of octets transmitted out of the interface, including framing characters. - 1.3.6.1.2.1.2.2.1.16 indexes: - labelname: ifIndex type: gauge lookups: - labels: - ifIndex labelname: ifDescr oid: 1.3.6.1.2.1.2.2.1.2 type: DisplayString - labels: [] labelname: ifIndex - name: ifOutUcastPkts oid: 1.3.6.1.2.1.2.2.1.17 type: counter help: The total number of packets that higher-level protocols requested be transmitted to a subnetwork-unicast address, including those that were discarded or not sent. - 1.3.6.1.2.1.2.2.1.17 indexes: - labelname: ifIndex type: gauge lookups: - labels: - ifIndex labelname: ifDescr oid: 1.3.6.1.2.1.2.2.1.2 type: DisplayString - labels: [] labelname: ifIndex - name: ifOutNUcastPkts oid: 1.3.6.1.2.1.2.2.1.18 type: counter help: The total number of packets that higher-level protocols requested be transmitted to a non- unicast (i.e., a subnetwork-broadcast or subnetwork-multicast) address, including those that were discarded or not sent. - 1.3.6.1.2.1.2.2.1.18 indexes: - labelname: ifIndex type: gauge lookups: - labels: - ifIndex labelname: ifDescr oid: 1.3.6.1.2.1.2.2.1.2 type: DisplayString - labels: [] labelname: ifIndex - name: ifOutDiscards oid: 1.3.6.1.2.1.2.2.1.19 type: counter help: The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being transmitted - 1.3.6.1.2.1.2.2.1.19 indexes: - labelname: ifIndex type: gauge lookups: - labels: - ifIndex labelname: ifDescr oid: 1.3.6.1.2.1.2.2.1.2 type: DisplayString - labels: [] labelname: ifIndex - name: ifOutErrors oid: 1.3.6.1.2.1.2.2.1.20 type: counter help: The number of outbound packets that could not be transmitted because of errors. - 1.3.6.1.2.1.2.2.1.20 indexes: - labelname: ifIndex type: gauge lookups: - labels: - ifIndex labelname: ifDescr oid: 1.3.6.1.2.1.2.2.1.2 type: DisplayString - labels: [] labelname: ifIndex - name: ifOutQLen oid: 1.3.6.1.2.1.2.2.1.21 type: gauge help: The length of the output packet queue (in packets). - 1.3.6.1.2.1.2.2.1.21 indexes: - labelname: ifIndex type: gauge lookups: - labels: - ifIndex labelname: ifDescr oid: 1.3.6.1.2.1.2.2.1.2 type: DisplayString - labels: [] labelname: ifIndex - name: ifSpecific oid: 1.3.6.1.2.1.2.2.1.22 type: OctetString help: A reference to MIB definitions specific to the particular media being used to realize the interface - 1.3.6.1.2.1.2.2.1.22 indexes: - labelname: ifIndex type: gauge lookups: - labels: - ifIndex labelname: ifDescr oid: 1.3.6.1.2.1.2.2.1.2 type: DisplayString - labels: [] labelname: ifIndex - name: upsIdentManufacturer oid: 1.3.6.1.2.1.33.1.1.1 type: DisplayString help: The name of the UPS manufacturer. - 1.3.6.1.2.1.33.1.1.1 - name: upsIdentModel oid: 1.3.6.1.2.1.33.1.1.2 type: DisplayString help: The UPS Model designation. - 1.3.6.1.2.1.33.1.1.2 - name: upsIdentUPSSoftwareVersion oid: 1.3.6.1.2.1.33.1.1.3 type: DisplayString help: The UPS firmware/software version(s) - 1.3.6.1.2.1.33.1.1.3 - name: upsIdentAgentSoftwareVersion oid: 1.3.6.1.2.1.33.1.1.4 type: DisplayString help: The UPS agent software version - 1.3.6.1.2.1.33.1.1.4 - name: upsIdentName oid: 1.3.6.1.2.1.33.1.1.5 type: DisplayString help: A string identifying the UPS - 1.3.6.1.2.1.33.1.1.5 - name: upsIdentAttachedDevices oid: 1.3.6.1.2.1.33.1.1.6 type: DisplayString help: A string identifying the devices attached to the output(s) of the UPS - 1.3.6.1.2.1.33.1.1.6 - name: upsBatteryStatus oid: 1.3.6.1.2.1.33.1.2.1 type: EnumAsStateSet help: The indication of the capacity remaining in the UPS system's batteries - 1.3.6.1.2.1.33.1.2.1 enum_values: 1: unknown 2: batteryNormal 3: batteryLow 4: batteryDepleted - name: upsSecondsOnBattery oid: 1.3.6.1.2.1.33.1.2.2 type: gauge help: If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less - 1.3.6.1.2.1.33.1.2.2 - name: upsEstimatedMinutesRemaining oid: 1.3.6.1.2.1.33.1.2.3 type: gauge help: An estimate of the time to battery charge depletion under the present load conditions if the utility power is off and remains off, or if it were to be lost and remain off. - 1.3.6.1.2.1.33.1.2.3 - name: upsEstimatedChargeRemaining oid: 1.3.6.1.2.1.33.1.2.4 type: gauge help: An estimate of the battery charge remaining expressed as a percent of full charge. - 1.3.6.1.2.1.33.1.2.4 - name: upsBatteryVoltage oid: 1.3.6.1.2.1.33.1.2.5 type: gauge help: The magnitude of the present battery voltage. - 1.3.6.1.2.1.33.1.2.5 - name: upsBatteryCurrent oid: 1.3.6.1.2.1.33.1.2.6 type: gauge help: The present battery current. - 1.3.6.1.2.1.33.1.2.6 - name: upsBatteryTemperature oid: 1.3.6.1.2.1.33.1.2.7 type: gauge help: The ambient temperature at or near the UPS Battery casing. - 1.3.6.1.2.1.33.1.2.7 - name: upsInputLineBads oid: 1.3.6.1.2.1.33.1.3.1 type: counter help: A count of the number of times the input entered an out-of-tolerance condition as defined by the manufacturer - 1.3.6.1.2.1.33.1.3.1 - name: upsInputNumLines oid: 1.3.6.1.2.1.33.1.3.2 type: gauge help: The number of input lines utilized in this device - 1.3.6.1.2.1.33.1.3.2 - name: upsInputLineIndex oid: 1.3.6.1.2.1.33.1.3.3.1.1 type: gauge help: The input line identifier. - 1.3.6.1.2.1.33.1.3.3.1.1 indexes: - labelname: upsInputLineIndex type: gauge - name: upsInputFrequency oid: 1.3.6.1.2.1.33.1.3.3.1.2 type: gauge help: The present input frequency. - 1.3.6.1.2.1.33.1.3.3.1.2 indexes: - labelname: upsInputLineIndex type: gauge - name: upsInputVoltage oid: 1.3.6.1.2.1.33.1.3.3.1.3 type: gauge help: The magnitude of the present input voltage. - 1.3.6.1.2.1.33.1.3.3.1.3 indexes: - labelname: upsInputLineIndex type: gauge - name: upsInputCurrent oid: 1.3.6.1.2.1.33.1.3.3.1.4 type: gauge help: The magnitude of the present input current. - 1.3.6.1.2.1.33.1.3.3.1.4 indexes: - labelname: upsInputLineIndex type: gauge - name: upsInputTruePower oid: 1.3.6.1.2.1.33.1.3.3.1.5 type: gauge help: The magnitude of the present input true power. - 1.3.6.1.2.1.33.1.3.3.1.5 indexes: - labelname: upsInputLineIndex type: gauge - name: upsOutputSource oid: 1.3.6.1.2.1.33.1.4.1 type: EnumAsStateSet help: The present source of output power - 1.3.6.1.2.1.33.1.4.1 enum_values: 1: other 2: none 3: normal 4: bypass 5: battery 6: booster 7: reducer - name: upsOutputFrequency oid: 1.3.6.1.2.1.33.1.4.2 type: gauge help: The present output frequency. - 1.3.6.1.2.1.33.1.4.2 - name: upsOutputNumLines oid: 1.3.6.1.2.1.33.1.4.3 type: gauge help: The number of output lines utilized in this device - 1.3.6.1.2.1.33.1.4.3 - name: upsOutputLineIndex oid: 1.3.6.1.2.1.33.1.4.4.1.1 type: gauge help: The output line identifier. - 1.3.6.1.2.1.33.1.4.4.1.1 indexes: - labelname: upsOutputLineIndex type: gauge - name: upsOutputVoltage oid: 1.3.6.1.2.1.33.1.4.4.1.2 type: gauge help: The present output voltage. - 1.3.6.1.2.1.33.1.4.4.1.2 indexes: - labelname: upsOutputLineIndex type: gauge - name: upsOutputCurrent oid: 1.3.6.1.2.1.33.1.4.4.1.3 type: gauge help: The present output current. - 1.3.6.1.2.1.33.1.4.4.1.3 indexes: - labelname: upsOutputLineIndex type: gauge - name: upsOutputPower oid: 1.3.6.1.2.1.33.1.4.4.1.4 type: gauge help: The present output true power. - 1.3.6.1.2.1.33.1.4.4.1.4 indexes: - labelname: upsOutputLineIndex type: gauge - name: upsOutputPercentLoad oid: 1.3.6.1.2.1.33.1.4.4.1.5 type: gauge help: The percentage of the UPS power capacity presently being used on this output line, i.e., the greater of the percent load of true power capacity and the percent load of VA. - 1.3.6.1.2.1.33.1.4.4.1.5 indexes: - labelname: upsOutputLineIndex type: gauge - name: upsBypassFrequency oid: 1.3.6.1.2.1.33.1.5.1 type: gauge help: The present bypass frequency. - 1.3.6.1.2.1.33.1.5.1 - name: upsBypassNumLines oid: 1.3.6.1.2.1.33.1.5.2 type: gauge help: The number of bypass lines utilized in this device - 1.3.6.1.2.1.33.1.5.2 - name: upsBypassLineIndex oid: 1.3.6.1.2.1.33.1.5.3.1.1 type: gauge help: The bypass line identifier. - 1.3.6.1.2.1.33.1.5.3.1.1 indexes: - labelname: upsBypassLineIndex type: gauge - name: upsBypassVoltage oid: 1.3.6.1.2.1.33.1.5.3.1.2 type: gauge help: The present bypass voltage. - 1.3.6.1.2.1.33.1.5.3.1.2 indexes: - labelname: upsBypassLineIndex type: gauge - name: upsBypassCurrent oid: 1.3.6.1.2.1.33.1.5.3.1.3 type: gauge help: The present bypass current. - 1.3.6.1.2.1.33.1.5.3.1.3 indexes: - labelname: upsBypassLineIndex type: gauge - name: upsBypassPower oid: 1.3.6.1.2.1.33.1.5.3.1.4 type: gauge help: The present true power conveyed by the bypass. - 1.3.6.1.2.1.33.1.5.3.1.4 indexes: - labelname: upsBypassLineIndex type: gauge - name: upsAlarmsPresent oid: 1.3.6.1.2.1.33.1.6.1 type: gauge help: The present number of active alarm conditions. - 1.3.6.1.2.1.33.1.6.1 - name: upsAlarmId oid: 1.3.6.1.2.1.33.1.6.2.1.1 type: gauge help: A unique identifier for an alarm condition - 1.3.6.1.2.1.33.1.6.2.1.1 indexes: - labelname: upsAlarmId type: gauge - name: upsAlarmDescr oid: 1.3.6.1.2.1.33.1.6.2.1.2 type: OctetString help: A reference to an alarm description object - 1.3.6.1.2.1.33.1.6.2.1.2 indexes: - labelname: upsAlarmId type: gauge - name: upsAlarmTime oid: 1.3.6.1.2.1.33.1.6.2.1.3 type: gauge help: The value of sysUpTime when the alarm condition was detected - 1.3.6.1.2.1.33.1.6.2.1.3 indexes: - labelname: upsAlarmId type: gauge - name: upsTestId oid: 1.3.6.1.2.1.33.1.7.1 type: OctetString help: The test is named by an OBJECT IDENTIFIER which allows a standard mechanism for the initiation of tests, including the well known tests identified in this document as well as those introduced by a particular implementation, i.e., as documented in the private enterprise MIB definition for the device - 1.3.6.1.2.1.33.1.7.1 - name: upsTestSpinLock oid: 1.3.6.1.2.1.33.1.7.2 type: gauge help: A spin lock on the test subsystem - 1.3.6.1.2.1.33.1.7.2 - name: upsTestResultsSummary oid: 1.3.6.1.2.1.33.1.7.3 type: EnumAsStateSet help: The results of the current or last UPS diagnostics test performed - 1.3.6.1.2.1.33.1.7.3 enum_values: 1: donePass 2: doneWarning 3: doneError 4: aborted 5: inProgress 6: noTestsInitiated - name: upsTestResultsDetail oid: 1.3.6.1.2.1.33.1.7.4 type: DisplayString help: Additional information about upsTestResultsSummary - 1.3.6.1.2.1.33.1.7.4 - name: upsTestStartTime oid: 1.3.6.1.2.1.33.1.7.5 type: gauge help: The value of sysUpTime at the time the test in progress was initiated, or, if no test is in progress, the time the previous test was initiated - 1.3.6.1.2.1.33.1.7.5 - name: upsTestElapsedTime oid: 1.3.6.1.2.1.33.1.7.6 type: gauge help: The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete - 1.3.6.1.2.1.33.1.7.6 - name: upsShutdownType oid: 1.3.6.1.2.1.33.1.8.1 type: EnumAsStateSet help: This object determines the nature of the action to be taken at the time when the countdown of the upsShutdownAfterDelay and upsRebootWithDuration objects reaches zero - 1.3.6.1.2.1.33.1.8.1 enum_values: 1: output 2: system - name: upsShutdownAfterDelay oid: 1.3.6.1.2.1.33.1.8.2 type: gauge help: Setting this object will shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdown) after the indicated number of seconds, or less if the UPS batteries become depleted - 1.3.6.1.2.1.33.1.8.2 - name: upsStartupAfterDelay oid: 1.3.6.1.2.1.33.1.8.3 type: gauge help: Setting this object will start the output after the indicated number of seconds, including starting the UPS, if necessary - 1.3.6.1.2.1.33.1.8.3 - name: upsRebootWithDuration oid: 1.3.6.1.2.1.33.1.8.4 type: gauge help: Setting this object will immediately shutdown (i.e., turn off) either the UPS output or the UPS system (as determined by the value of upsShutdownType at the time of shutdown) for a period equal to the indicated number of seconds, after which time the output will be started, including starting the UPS, if necessary - 1.3.6.1.2.1.33.1.8.4 - name: upsAutoRestart oid: 1.3.6.1.2.1.33.1.8.5 type: EnumAsStateSet help: Setting this object to 'on' will cause the UPS system to restart after a shutdown if the shutdown occurred during a power loss as a result of either a upsShutdownAfterDelay or an internal battery depleted condition - 1.3.6.1.2.1.33.1.8.5 enum_values: 1: "on" 2: "off" - name: upsConfigInputVoltage oid: 1.3.6.1.2.1.33.1.9.1 type: gauge help: The magnitude of the nominal input voltage - 1.3.6.1.2.1.33.1.9.1 - name: upsConfigInputFreq oid: 1.3.6.1.2.1.33.1.9.2 type: gauge help: The nominal input frequency - 1.3.6.1.2.1.33.1.9.2 - name: upsConfigOutputVoltage oid: 1.3.6.1.2.1.33.1.9.3 type: gauge help: The magnitude of the nominal output voltage - 1.3.6.1.2.1.33.1.9.3 - name: upsConfigOutputFreq oid: 1.3.6.1.2.1.33.1.9.4 type: gauge help: The nominal output frequency - 1.3.6.1.2.1.33.1.9.4 - name: upsConfigOutputVA oid: 1.3.6.1.2.1.33.1.9.5 type: gauge help: The magnitude of the nominal Volt-Amp rating. - 1.3.6.1.2.1.33.1.9.5 - name: upsConfigOutputPower oid: 1.3.6.1.2.1.33.1.9.6 type: gauge help: The magnitude of the nominal true power rating. - 1.3.6.1.2.1.33.1.9.6 - name: upsConfigLowBattTime oid: 1.3.6.1.2.1.33.1.9.7 type: gauge help: The value of upsEstimatedMinutesRemaining at which a lowBattery condition is declared - 1.3.6.1.2.1.33.1.9.7 - name: upsConfigAudibleStatus oid: 1.3.6.1.2.1.33.1.9.8 type: EnumAsStateSet help: The requested state of the audible alarm - 1.3.6.1.2.1.33.1.9.8 enum_values: 1: disabled 2: enabled 3: muted - name: upsConfigLowVoltageTransferPoint oid: 1.3.6.1.2.1.33.1.9.9 type: gauge help: The minimum input line voltage allowed before the UPS system transfers to battery backup. - 1.3.6.1.2.1.33.1.9.9 - name: upsConfigHighVoltageTransferPoint oid: 1.3.6.1.2.1.33.1.9.10 type: gauge help: The maximum line voltage allowed before the UPS system transfers to battery backup. - 1.3.6.1.2.1.33.1.9.10 version: 1