kube/monitoring/node-exporter.yaml

432 lines
18 KiB
YAML

---
apiVersion: monitoring.coreos.com/v1
kind: Probe
metadata:
name: nodes-proxmox
spec:
scrapeTimeout: 30s
targets:
staticConfig:
static:
- nas.mgmt.k-space.ee:9100
- pve1.proxmox.infra.k-space.ee:9100
- pve2.proxmox.infra.k-space.ee:9100
- pve8.proxmox.infra.k-space.ee:9100
- pve9.proxmox.infra.k-space.ee:9100
relabelingConfigs:
- sourceLabels: [__param_target]
targetLabel: instance
- sourceLabels: [__param_target]
targetLabel: __address__
prober:
url: localhost
path: /metrics
metricRelabelings:
- sourceLabels: [__address__]
targetLabel: target
---
apiVersion: monitoring.coreos.com/v1
kind: PrometheusRule
metadata:
name: node-exporter
spec:
groups:
- name: node-exporter
rules:
- alert: ZfsDegradedPool
expr: node_zfs_zpool_state{state!="online"} > 0
for: 1m
labels:
severity: critical
annotations:
summary: ZFS offline pool (instance {{ $labels.instance }})
description: "A ZFS zpool is in a unexpected state: {{ $labels.state }}.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostHighLoad
expr: sum(node_load1{}) by (instance) / count(node_cpu_seconds_total{mode="user"}) by (instance) > 2.5
for: 15m
labels:
severity: warning
annotations:
summary: Host under high load
description: Many processes are queued up for execution
- alert: HostOutOfMemory
expr: (node_memory_Cached_bytes + node_memory_Buffers_bytes + node_memory_MemFree_bytes ) / node_memory_MemTotal_bytes * 100 < 20
for: 2m
labels:
severity: warning
annotations:
summary: Host out of memory (instance {{ $labels.instance }})
description: Node memory is filling up (< 10% left)
- alert: HostMemoryUnderMemoryPressure
expr: rate(node_vmstat_pgmajfault[1m]) > 1000
for: 2m
labels:
severity: warning
annotations:
summary: Host memory under memory pressure (instance {{ $labels.instance }})
description: The node is under heavy memory pressure. High rate of major page faults
- alert: HostUnusualNetworkThroughputIn
expr: sum by (instance) (rate(node_network_receive_bytes_total[2m])) > 800e+06
for: 1h
labels:
severity: warning
annotations:
summary: Host unusual network throughput in (instance {{ $labels.instance }})
description: Host network interfaces are probably receiving too much data (> 800 MB/s)
- alert: HostUnusualNetworkThroughputOut
expr: sum by (instance) (rate(node_network_transmit_bytes_total[2m])) > 800e+06
for: 1h
labels:
severity: warning
annotations:
summary: Host unusual network throughput out (instance {{ $labels.instance }})
description: Host network interfaces are probably sending too much data (> 800 MB/s)
- alert: HostUnusualDiskReadRate
expr: sum by (instance) (rate(node_disk_read_bytes_total[2m])) > 500e+06
for: 1h
labels:
severity: warning
annotations:
summary: Host unusual disk read rate (instance {{ $labels.instance }})
description: Disk is probably reading too much data (> 500 MB/s)
- alert: HostUnusualDiskWriteRate
expr: sum by (instance) (rate(node_disk_written_bytes_total[2m])) > 500e+06
for: 1h
labels:
severity: warning
annotations:
summary: Host unusual disk write rate (instance {{ $labels.instance }})
description: Disk is probably writing too much data (> 500 MB/s)
# Please add ignored mountpoints in node_exporter parameters like
# "--collector.filesystem.ignored-mount-points=^/(sys|proc|dev|run)($|/)".
# Same rule using "node_filesystem_free_bytes" will fire when disk fills for non-root users.
- alert: HostOutOfDiskSpace
expr: (node_filesystem_avail_bytes * 100) / node_filesystem_size_bytes < 10 and ON (instance, device, mountpoint) node_filesystem_readonly == 0
for: 2m
labels:
severity: warning
annotations:
summary: Host out of disk space (instance {{ $labels.instance }})
description: Disk is almost full (< 10% left)
# Please add ignored mountpoints in node_exporter parameters like
# "--collector.filesystem.ignored-mount-points=^/(sys|proc|dev|run)($|/)".
# Same rule using "node_filesystem_free_bytes" will fire when disk fills for non-root users.
- alert: HostDiskWillFillIn24Hours
expr: (node_filesystem_avail_bytes * 100) / node_filesystem_size_bytes < 10 and ON (instance, device, mountpoint) predict_linear(node_filesystem_avail_bytes{fstype!~"tmpfs"}[1h], 24 * 3600) < 0 and ON (instance, device, mountpoint) node_filesystem_readonly == 0
for: 2m
labels:
severity: warning
annotations:
summary: Host disk will fill in 24 hours (instance {{ $labels.instance }})
description: Filesystem is predicted to run out of space within the next 24 hours at current write rate
- alert: HostOutOfInodes
expr: node_filesystem_files_free{mountpoint ="/rootfs"} / node_filesystem_files{mountpoint="/rootfs"} * 100 < 10 and ON (instance, device, mountpoint) node_filesystem_readonly{mountpoint="/rootfs"} == 0
for: 2m
labels:
severity: warning
annotations:
summary: Host out of inodes (instance {{ $labels.instance }})
description: Disk is almost running out of available inodes (< 10% left)
- alert: HostInodesWillFillIn24Hours
expr: node_filesystem_files_free{mountpoint ="/rootfs"} / node_filesystem_files{mountpoint="/rootfs"} * 100 < 10 and predict_linear(node_filesystem_files_free{mountpoint="/rootfs"}[1h], 24 * 3600) < 0 and ON (instance, device, mountpoint) node_filesystem_readonly{mountpoint="/rootfs"} == 0
for: 2m
labels:
severity: warning
annotations:
summary: Host inodes will fill in 24 hours (instance {{ $labels.instance }})
description: Filesystem is predicted to run out of inodes within the next 24 hours at current write rate
- alert: HostUnusualDiskReadLatency
expr: rate(node_disk_read_time_seconds_total[1m]) / rate(node_disk_reads_completed_total[1m]) > 0.1 and rate(node_disk_reads_completed_total[1m]) > 0
for: 2m
labels:
severity: warning
annotations:
summary: Host unusual disk read latency (instance {{ $labels.instance }})
description: Disk latency is growing (read operations > 100ms)
- alert: HostUnusualDiskWriteLatency
expr: rate(node_disk_write_time_seconds_total[1m]) / rate(node_disk_writes_completed_total[1m]) > 0.1 and rate(node_disk_writes_completed_total[1m]) > 0
for: 2m
labels:
severity: warning
annotations:
summary: Host unusual disk write latency (instance {{ $labels.instance }})
description: Disk latency is growing (write operations > 100ms)
- alert: HostCpuStealNoisyNeighbor
expr: avg by(instance) (rate(node_cpu_seconds_total{mode="steal"}[5m])) * 100 > 10
for: 0m
labels:
severity: warning
annotations:
summary: Host CPU steal noisy neighbor (instance {{ $labels.instance }})
description: CPU steal is > 10%. A noisy neighbor is killing VM performances or a spot instance may be out of credit.
# 1000 context switches is an arbitrary number.
# Alert threshold depends on nature of application.
# Please read: https://github.com/samber/awesome-prometheus-alerts/issues/58
- alert: HostContextSwitching
expr: (rate(node_context_switches_total[5m])) / (count without(cpu, mode) (node_cpu_seconds_total{mode="idle"})) > 50000
for: 0m
labels:
severity: warning
annotations:
summary: Host context switching (instance {{ $labels.instance }})
description: Context switching is growing on node (> 50000 / s)
- alert: HostSwapIsEnabled
expr: node_memory_SwapTotal_bytes > 0
for: 0m
labels:
severity: warning
annotations:
summary: Swap is discouraged nowadays
- alert: HostPhysicalComponentTooHot
expr: node_hwmon_temp_celsius > 75
for: 5m
labels:
severity: warning
annotations:
summary: Host physical component too hot (instance {{ $labels.instance }})
description: Physical hardware component too hot
- alert: HostNodeOvertemperatureAlarm
expr: node_hwmon_temp_alarm == 1
for: 0m
labels:
severity: critical
annotations:
summary: Host node overtemperature alarm (instance {{ $labels.instance }})
description: Physical node temperature alarm triggered
- alert: HostRaidArrayGotInactive
expr: node_md_state{state="inactive"} > 0
for: 0m
labels:
severity: critical
annotations:
summary: Host RAID array got inactive (instance {{ $labels.instance }})
description: RAID array {{ $labels.device }} is in degraded state due to one or more disks failures. Number of spare drives is insufficient to fix issue automatically.
- alert: HostRaidDiskFailure
expr: node_md_disks{state="failed"} > 0
for: 2m
labels:
severity: warning
annotations:
summary: Host RAID disk failure (instance {{ $labels.instance }})
description: At least one device in RAID array on {{ $labels.instance }} failed. Array {{ $labels.md_device }} needs attention and possibly a disk swap
- alert: HostOomKillDetected
expr: increase(node_vmstat_oom_kill[1m]) > 0
for: 0m
labels:
severity: warning
annotations:
summary: Host OOM kill detected (instance {{ $labels.instance }})
description: OOM kill detected
- alert: HostEdacCorrectableErrorsDetected
expr: increase(node_edac_correctable_errors_total[1m]) > 0
for: 0m
labels:
severity: info
annotations:
summary: Host EDAC Correctable Errors detected (instance {{ $labels.instance }})
description: "Host {{ $labels.instance }} has had {{ printf \"%.0f\" $value }} correctable memory errors reported by EDAC in the last 5 minutes.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostEdacUncorrectableErrorsDetected
expr: node_edac_uncorrectable_errors_total > 0
for: 0m
labels:
severity: warning
annotations:
summary: Host EDAC Uncorrectable Errors detected (instance {{ $labels.instance }})
description: "Host {{ $labels.instance }} has had {{ printf \"%.0f\" $value }} uncorrectable memory errors reported by EDAC in the last 5 minutes.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostNetworkReceiveErrors
expr: rate(node_network_receive_errs_total[2m]) / rate(node_network_receive_packets_total[2m]) > 0.01
for: 2m
labels:
severity: warning
annotations:
summary: Host Network Receive Errors (instance {{ $labels.instance }})
description: "Host {{ $labels.instance }} interface {{ $labels.device }} has encountered {{ printf \"%.0f\" $value }} receive errors in the last two minutes.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostNetworkTransmitErrors
expr: rate(node_network_transmit_errs_total[2m]) / rate(node_network_transmit_packets_total[2m]) > 0.01
for: 2m
labels:
severity: warning
annotations:
summary: Host Network Transmit Errors (instance {{ $labels.instance }})
description: "Host {{ $labels.instance }} interface {{ $labels.device }} has encountered {{ printf \"%.0f\" $value }} transmit errors in the last two minutes.\n VALUE = {{ $value }}\n LABELS = {{ $labels }}"
- alert: HostNetworkInterfaceSaturated
expr: (rate(node_network_receive_bytes_total{device!~"^tap.*"}[1m]) + rate(node_network_transmit_bytes_total{device!~"^tap.*"}[1m])) / node_network_speed_bytes{device!~"^tap.*"} > 0.8
for: 1m
labels:
severity: warning
annotations:
summary: Host Network Interface Saturated (instance {{ $labels.instance }})
description: "The network interface {{ $labels.interface }} on {{ $labels.instance }} is getting overloaded."
- alert: HostNetworkBondDegraded
expr: node_bonding_active != node_bonding_slaves {master=~"bond.*"}
for: 2m
labels:
severity: warning
annotations:
summary: Host Network Bond Degraded
- alert: HostConntrackLimit
expr: node_nf_conntrack_entries / node_nf_conntrack_entries_limit > 0.8
for: 5m
labels:
severity: warning
annotations:
summary: Host conntrack limit (instance {{ $labels.instance }})
description: The number of conntrack is approching limit
- alert: HostClockSkew
expr: (node_timex_offset_seconds > 0.05 and deriv(node_timex_offset_seconds[5m]) >= 0) or (node_timex_offset_seconds < -0.05 and deriv(node_timex_offset_seconds[5m]) <= 0)
for: 2m
labels:
severity: warning
annotations:
summary: Host clock skew (instance {{ $labels.instance }})
description: Clock skew detected. Clock is out of sync.
- alert: HostClockNotSynchronising
expr: min_over_time(node_timex_sync_status[1m]) == 0 and node_timex_maxerror_seconds >= 16
for: 2m
labels:
severity: warning
annotations:
summary: Host clock not synchronising (instance {{ $labels.instance }})
description: Clock not synchronising.
---
apiVersion: monitoring.coreos.com/v1
kind: PrometheusRule
metadata:
name: smart
spec:
groups:
- name: smart
rules:
- alert: SmartSSDWriteRateTooHigh
expr: rate(smartmon_total_lbas_written_raw_value[72h]) * 512 > 10000000
for: 5m
labels:
severity: warning
annotations:
summary: SSD write rate exceeds 10MB/s
description: At this rate the SSD will be worn out before warranty period expires
---
apiVersion: monitoring.coreos.com/v1
kind: PrometheusRule
metadata:
name: temperatures
spec:
groups:
- name: temperatures
rules:
- alert: HighDiskTemperature
expr: smartmon_airflow_temperature_cel_raw_value > 45 or smartmon_temperature_celsius_raw_value > 45
for: 10m
labels:
severity: critical
annotations:
summary: High HDD/SSD temperature indicates high ambient temperature
- alert: HighChipsetTemperature
expr: node_hwmon_temp_celsius > 65
for: 10m
labels:
severity: warning
annotations:
summary: High chipset (CPU, NB) temperature indicates insufficient or failing fans
- alert: LowDiskTemperature
expr: smartmon_airflow_temperature_cel_raw_value < 10 or smartmon_temperature_celsius_raw_value < 10
for: 10m
labels:
severity: critical
annotations:
summary: Low HDD/SSD temperature indicates low ambient temperature and stuck server room exhaust fan relay
---
apiVersion: monitoring.coreos.com/v1
kind: PodMonitor
metadata:
name: node-exporter
spec:
selector:
matchLabels:
app: node-exporter
podMetricsEndpoints:
- port: web
scrapeTimeout: 30s
relabelings:
- sourceLabels: [__meta_kubernetes_pod_node_name]
targetLabel: node
---
apiVersion: v1
kind: ServiceAccount
metadata:
name: node-exporter
---
apiVersion: apps/v1
kind: DaemonSet
metadata:
labels:
app: node-exporter
name: node-exporter
spec:
revisionHistoryLimit: 0
selector:
matchLabels:
app: node-exporter
template:
metadata:
labels:
app: node-exporter
spec:
containers:
- name: node-exporter
args:
- --web.listen-address=0.0.0.0:9101
- --no-collector.bonding
- --no-collector.fibrechannel
- --no-collector.infiniband
- --no-collector.nfs
- --no-collector.nfsd
- --no-collector.nvme
- --no-collector.zfs
- --no-collector.tapestats
- --no-collector.wifi
- --collector.filesystem.mount-points-exclude=^/(dev|proc|sys|var/lib/docker|var/lib/kubelet/pods|run)(/.+)?$
- --collector.netclass.ignored-devices=^(veth|cali|vxlan|cni|vnet|tap|lo|wg)
- --collector.netdev.device-exclude=^(veth|cali|vxlan|cni|vnet|tap|lo|wg)
- --collector.diskstats.ignored-devices=^(sr|loop)[0-9][0-9]*$
image: mirror.gcr.io/prom/node-exporter:v1.8.2
resources:
limits:
cpu: 50m
memory: 180Mi
requests:
cpu: 5m
memory: 20Mi
volumeMounts:
- name: sys
mountPath: /sys
readOnly: true
- name: proc
mountPath: /proc
readOnly: true
ports:
- containerPort: 9101
name: web
securityContext:
runAsGroup: 65532
runAsNonRoot: true
runAsUser: 65532
readOnlyRootFilesystem: true
hostNetwork: true
hostPID: true
priorityClassName: system-node-critical
securityContext:
runAsNonRoot: true
runAsUser: 65534
serviceAccountName: node-exporter
tolerations:
- operator: Exists
volumes:
- name: sys
hostPath:
path: /sys
- name: proc
hostPath:
path: /proc